9500 Series Closer

Ideal for high use openings, the Norton 9500 Series Cast Iron door closer offers the durability, flexibility and strength required to meet the needs of your facility. For interior or exterior doors, this ANSI/BHMA Grade 1 closer features a clean, modern cover aesthetic and durable cast iron body that can be used in a variety of institutional and educational environments requiring ADA compliance.


Door closers shall be of rack and pinion construction with a cold headed heat-treated steel spindle and a forged steel piston precision machined and heat treated. The case shall be of cast iron. Closers shall have a heavy-duty, forged steel main arm.

Optional arms shall include parallel rigid, parallel rigid friction hold open, regular rigid, CloserPlus®, CloserPlus® hold open, Unitrol®, Unitrol® hold open and track assemblies.

The following size options shall be available: Fully adjustable spring power to accommodate sizes 1 through 6.

All sizes shall be accommodated in one closer body. Closing shall be controlled by two valves — one to control closing speed and one to control latching speed. Valves shall be concealed against unauthorized adjustment and be non-critical with “O” ring seals.

Delayed action shall be available and shall be accomplished with a separate valve.

Closers shall be available with an adjustable backcheck intensity valve with a safety feature that automatically relieves internal pressure when backcheck has reached the desired adjustment level. Valves shall be accessible without removing the closer from the door.

Closers shall be available with a backcheck intensity valve. Backcheck begins at approximately 70 degrees of door opening for all applications. This valve shall be operative on regular, top jamb, parallel arm, and track type mountings. Closers shall be surface applied with rectangular cover. Closers shall not project over 2-1/4", and shall be capable of mounting on 1-3/4" top rail or inverted mounting on 1-3/4" top jamb. Full cover with security fasteners shall be available. Closers without hold open shall be regularly furnished with power adjustment arm bracket capable of providing a 15% power adjustment. A mounting bracket to attach the closer shall be regularly furnished. Hydraulic fluid shall be of a type requiring no seasonal valve readjustment due to extreme temperature variations.

Closers mounted regular arm, top jamb and parallel arm shall allow for full 180° door opening.

Closers with non-hold open arms shall be listed by Underwriters Laboratories.

All closers with metal covers shall be available in architectural finishes to match corresponding door hardware.


Bright Brass

Satin Brass

Bright Bronze

Satin Bronze

Satin Nickel 

Dark Oxidized
Satin Bronze,

Bright Chrome 

Satin Chrome 


Statuary Bronze

Dull Bronze

Medium Amber



  • Exceeds 25 million cycles
  • Cast iron closer body
  • Unique cover design featuring Norton branding
  • Non-handed
  • Staked valves
  • Standard, separate and independent, latch, sweep and backcheck intensity valves
  • 2-1/4" projection
  • 1-1/2" diameter piston
  • Closer mounting plate for easy installation
  • Tri-style® packaging: packed for reqular, top jamb or parallel arm mounting
  • Adjustable spring size 1-6
  • Molded plastic cover
  • All standard arm applications allow doors to swing 180°, conditions permitting


Optional Features

  • Heavy-duty arms: Regular Rigid, Parallel Rigid, CloserPlus®, Parallel Rigid Offset and Unitrol®



  • Delayed Action



Typical Applications

Recommended for interior or exterior doors including:



  • Schools/Universities
  • Office Buildings
  • Healthcare Facilities




  • UL Certified
  • ANSI/BHMA A156.4 Certified
  • Americans with Disabilities Act (ADA) and ANSI/BHMA standard A117.1




  • Meets requirements for UL10C for positive pressure
  • 25-year limited warranty




Customer Service:
800.438.1951 x Ext 6701
(8am - 4:30pm Eastern)


Technical Product Support:
800.438.1951 x Ext 6030
(8am - 4:30pm Eastern)

Sales Agency Locator