1600BC/1601 Series

The 1600BC/1601 Series Door Closers are designed to fit almost any application and are the choice of engineers worldwide. Ideal for use with aluminum storefront doors and frames, these closers have a history of proven quality and tradition.

Specifications

1601 Series
Closers for interior and exterior doors shall be full rack-and-pinion type with cast aluminum alloy shell. Closers shall be surface mounted and shall project no more that 2-7/8" from the surface of the door. Closers shall be non-handed to permit installation on doors of either hand. Closer fluid shall contain lubricity and anti-oxidation agents. Closer fluid shall maintain stable viscosity to allow door closer to perform in temperatures ranging from extremely high to as low as -40°F. Closers shall have multi-size spring power adjustment to permit setting of spring from (1 through 4) or (3 through 6). Closers shall have two non-critical valves, hex key adjusted, to independently regulate sweep and latch speed. Closers shall have adjustable backcheck cushioning controlled by a hex key adjusted valve. [Closers shall have adjustable delayed-action closing controlled by a hex key adjustable valve.] [Closer body shall be enclosed in/concealed with a full molded cover.] [Closers shall be highly corrosion resistant and shall have all external body components of aluminum, zinc alloy or stainless steel material and all stainless steel fasteners.] Regular arm and top jamb closers shall have a non-hold open shoe permitting 15% ( +/- 7-1/2% ) power adjustment. ** [1601] [1601BF] [1601SS].
**For special arms insert the appropriate arm specification here.
 
1600BC Series
Closers for interior and exterior doors shall be full rack-and-pinion type with cast aluminum alloy shell. Closers shall be surface mounted and shall project no more that 2-7/8" from the surface of the door. Closers shall be non-handed to permit installation of doors of either hand. Closer fluid shall contain lubricity and anti-oxidation agents. Closer fluid shall maintain stable viscosity to allow the door closer to perform in temperatures ranging from extremely high to as low as -40°F. Closers shall be sized for each door. Closers shall have two non-critical valves, hex key adjusted, to independently regulate sweep and latch speed. [Closers shall have adjustable backcheck cushioning controlled by a hex key adjusted valve.] [Closers shall have adjustable delayed action closing controlled by a hex key adjusted valve.] Regular arm and top jamb closers shall have a non-hold open shoe permitting 15% (+/-7-1/2%) power adjustment.** [1600BC]. 
**For special arms insert the appropriate arm specification here
 
**Unitrol® Arm
Door closers shall have built in-door stop [and holder] effective at one point selected at installation, from 85° - 115° in five-degree increments. Door stop shall be cushioned by a shock-absorbing heavy-duty spring action effective at the [soffit plate] [arm shoe] pivot. [Closers shall be provided for parallel arm installation using rigid steel main arm and secondary arm lengths proportional to the door width to reduce racking at the hinge/pivot.] [Closers shall be provided for top jamb installation using steel, rigid main arm and telescoping secondary arm adequate for the frame reveal of the openings.] (Closer arm shall have ball and detent hold open feature that can be engaged or disengaged by 1/4 turn of mechanism; and hold open strength shall be adjustable.)
 
**CloserPlus® Arm
Door closers shall have built-in door stop [and holder] effective at one point selected at installation, from 85° - 110° in five-degree increments. Door stop mechanism shall be reversible and attached to soffit plate. [Hold open mechanism shall have engage/disengage and strength selection actuated by thumbturn.] Closers shall be provided for parallel arm installation using rigid steel main and secondary arm.
 
**CloserPlus Spring™ Arm
Door closers shall have built in door stop [and holder] effective at one point selected at installation, from 85° - 110° in five-degree increments. Door stop mechanism shall have a buffer spring that engages prior to the dead stop feature, reducing shock loads to the door and frame assembly. Door stop mechanism shall be reversible and attached to soffit plate. [Hold open mechanism shall have engage/disengage and strength selection actuated by thumbturn.] Closers shall be provided for parallel installation using rigid steel main and secondary arm.

Finishes
556
556
White
605
605*
Bright Brass

606
606*
 Satin Brass

611
611*
Bright Bronze 

612
612*
 Satin Bronze
619
619*
Satin Nickel
625
625*
 Bright Chrome
626
626*
 Satin Chrome
 
689
Aluminum

690
Statuary Bronze  

691
Dull Bronze 

693
Black

694
Medium Amber

696
Gold

     

*Only available on arms

Features

  • 1600BC: Sized springs 3 or 4
  • 1601: Adjustable spring sizes 3-6
  • 1601BF: Adjustable spring sizes 1-4
  • Exceeds 12 million cycles (independently verified)
  • Non-handed
  • Rack and pinion design
  • Cast aluminum body
  • 2-7/8" (73mm) projection
  • 1-3/8" (35mm) diameter piston

...

  • 5/8" (16mm) diameter pinion journals
  • Standard, separate and independent, latch, sweep and backcheck intensity valves
  • Tri-Style® packaging (regular arm, top jamb and parallel arm mounting)
  • All standard arm applications allow doors to swing 180°, conditions permitting
  • Staked valves

Optional Features

  • Delayed action (in lieu of backcheck). Specify 1601DA or 1601BFDA
  • Corrosion-resistant model (non-hold open only). Specify 1601SS or 1601BFSS. (Not tri-packed)

 

 

 

  • Molded plastic cover. Specify suffix P
  • Heavy-duty arms: Parallel Rigid, CloserPlus®, CloserPlus Spring™, and Unitrol®

 

 

Typical Applications

Recommended on interior or exterior doors including:

 

 

  • Aluminum Storefronts
  • Office Doors
  • Utility Closets
  • Storage Rooms

Certifications

  • ANSI/BHMA A156.4, Grade 1 certified
  • UL listed
  • UL10c compliant for positive pressure

 

 

 

  • ADA compliant (1601BF)
  • 15-year limited warranty

Questions?

Customer Service:
800.438.1951 x Ext 6701
(8am - 4:30pm Eastern)

 

Technical Product Support:
800.438.1951 x Ext 6030
(8am - 4:30pm Eastern)

Sales Agency Locator