Norton Rixson’s 6200 Series is a cost effective electromechanical low energy operator offering intelligent functions, such as power close, latch assist and obstruction detection. Specifically designed for high traffic openings applications requiring a narrow profile to blend more seamlessly with the frame while fitting challenging applications with minimal overhead space. Complete with electric lock interface, touchless activation support, and mobile device Wi-Fi programming for easy installation and setup.

Specifications

Door Control (interior) (exterior) closing force shall be adjustable to ensure adequate closing control. Door Operator shall simulate conventional door closer opening and closing forces unless the power operator motor is activated. Door Operator shall have electronic backcheck to cushion the door speed if door is opened violently. [(Door Operator shall be AUTOMATICALLY ACTIVATED by either a slight push or pull in the direction of opening swing - Push & Go.) (Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e. wall switch, etc.) (Door Operator shall be both AUTOMATICALLY ACTIVATED and SELECTIVELY ACTIVATED.)] Operator shall have selectable motor power close to provide additional closing force to overcome conditions that may prevent door from latching. Unit shall have delay switches for motor activation, electric lock interfacing, and hold open time. Units shall interface with electric strikes or similar products and have 24VDC @ 0.4A maximum output for connection of electric strike, lock, radio frequency receiver, etc. Unit shall have a three-position Selector Mode Switch that will permit the unit to be switched "ON" to monitor for function inputs, switch to "H/O" for infinite hold open function or switched "OFF" which will disable function inputs allowing unit to be used as a manual door closer. Unit shall be U.L. Listed for automatic closing door. The Unit shall be adjustable to provide compliance with the requirements of the Americans with Disabilities Act (ADA). Unit shall be certified by BHMA to meet A156.19 requirements. Unit shall meet UL325/991, UL10C standards

Finishes

689
Aluminum

690
Statuary Bronze


BSP
Black Suede Powder Coat


WSP
White Suede Powder Coat

Downloads

Catalog

Brochure

Installation Instructions*

Sell Sheet

*Note: Wiring Diagrams are included in installation instructions document

Features

  • Push and pull side mounting
  • Non-handed
  • Activated by push button, hands-free and RF devices
  • Maximum door size: 200 lbs. at 48" wide

  • Aesthetically pleasing, slim profile
  • Modular design
  • Adjustable opening force
  • Adjustable closing power
  • Wi-Fi Interface
  • 2 year limited warranty

Functions

  • Adjustable Hold Open
    • Amount of time a door will stay in the full open position after an activation
  • Emergency Interface Relay (fire panel input)
    • Door closes and ignores any activation input until signal is discontinued
  • Infinite Hold Open
    • Door will hold open at set position until power is turned off
  • Latch Assist
    • At closed position, after an activation, the door is pulled in
    • After the door has closed, the door is pulled in to assist with latch release/engagement
  • Obstruction Detection
    • Open: door closes if it hits an obstruction while opening
    • Close: door will reverse to open position if it hits an obstruction while closing
    • Close (Selectable - stop on stall): door will stop once it hits an obstruction and will rest against the obstruction until removed
  • Open Delay
    • Delays operator opening for locking hardware

  • Outside Push Button Disable
    • When contact is closed, outside push button is disabled
  • Power Assist
    • Senses the door is being opened manually and applies small amount of power to assist user in opening the door with force less than 5 lbs.
    • Door opens only as far as it is moved manually, then closes once released
  • Power Close
    • Additional force to assist door closing between 7° and 2°
  • Presence Detector Input
    • Input for external sensor to detect presence at door open or close position only
  • Push & Go
    • As the door is manually opened, the operator "senses" movement and opens door to the full-open position
  • Selector Mode Switch
    • Off - Disables signal inputs unless Blow Open is activated
    • On - Activates signal inputs
    • Hold Open - Activates the unit (unless blow closed is activated on 6300) to the hold open position

Benefits

MODULAR DESIGN

  • One person install
  • Backplate serves as a template to simplify and speed installation

 

SLIM PROFILE

  • Blends seamlessly with frame
  • Fits challenging openings

SIMPLE CONTROLS

  • Easy to set up
  • Intelligent features

Applications

Moderate to high traffic openings are ideal applications for the 6200 Series Low Energy Operator. Whether an interior or exterior door, the 6200 Series is a low energy door control solution that allows facilities to meet ADA (Americans with Disabilities Act) requirements by enabling a door to be operated through the use of push buttons, wave switches or hands-free radio frequency devices.

  • Schools
  • Theatres
  • Office Buildings
  • Restaurants
  • Retail
  • Banking
  • Public Entrances

Electrical Data

  • Power input 120 VAC, 3A, 60Hz
  • Max current draw 1.5A
  • Power output 24VDC @ 0.4A max draw (less accessories)

Certifications

  • ANSI/BHMA A156.19 certified
  • UL325/991 certified
  • UL10C listed for positive pressure fire test

  • Complies with requirements for the Americans with Disabilities Act (A.D.A)
  • Manufactured in an ISO 9001 and ISO 14001 certified facility