The Norton 6300 Series Low Energy Operator offers a broad set of intelligent functions, such as power close, latch assist and obstruction detection to safely secure a variety of moderate to high traffic openings. A unique design with one of the slimmest profiles available allows the 6300 to blend more seamlessly with the frame while fitting challenging applications with minimal header space. A modular design, simple controls, and new wifi interface via a mobile device make for easy installation and setup.

Specifications

Door Control (interior) (exterior) closing force shall be adjustable to ensure adequate closing control. Door Operator shall simulate conventional door closer opening and closing forces unless the power operator motor is activated. Door Operator shall have electronic backcheck to cushion the door speed if door is opened violently. [(Door Operator shall be AUTOMATICALLY ACTIVATED by either a slight push or pull in the direction of opening swing - Push and Go.) (Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e. wall switch, etc.) (Door Operator shall be both AUTOMATICALLY ACTIVATED and SELECTIVELY ACTIVATED.)] Operator shall have selectable power close to provide additional closing force to overcome conditions that may prevent door from latching. Unit shall have delay switches for motor activation, electric lock interfacing, and hold open time. Units shall interface with latch assist exit devices or similar products and have 24VDC @ 1.3A maximum (less accessories) output for connection of electric strike, lock, radio frequency receiver, etc. Unit shall have a three-position Selector Mode Switch that will permit the unit to be switched "ON" to monitor for function inputs, switch to "H/O" for infinite hold open function or switched "OFF" which will disable function inputs allowing unit to be used as a manual door closer. Unit shall be U.L. Listed for automatic closing door. The Unit shall be adjustable to provide compliance with the requirements of the Americans with Disabilities Act (ADA). Unit shall be certified by BHMA to meet A156.19 requirements. Unit shall meet UL325/991, UL10C standards.

Finishes

689
Aluminum

690
Statuary Bronze


BSP
Black Suede Powder Coat


WSP
White Suede Powder Coat

Downloads

Catalog

Brochure

Installation Instructions*

Templates

Videos

*Note: Wiring Diagrams are included in installation instructions document

Features

  • Push and pull side mounting
  • Non-handed
  • Activated by push button, hands-free and RF devices
  • Door Width (single or pair): min 36", max 48"
  • Door Weight: 200 lbs.
  • Aesthetically pleasing, slim profile
  • Modular Design
  • LCD Screen
  • Wifi Interface
  • Push & Go (selectable)
  • Obstruction detection (open and close)

...

  • Modular design
  • Latch assist feature for enhanced security
  • Power Close
  • Selectable mode switch (off, on, hold open)
  • Adjustable opening force
  • Adjustable closing power
  • Blow open and blow close for smoke ventilation
  • 2 year limited warranty

Functions

  • Power Assist
    • Senses the door is being opened manually and applies small amount of power to assist user in opening the door with force less than 5 lbs.
    • Door opens only as far as it is moved manually, then closes once released
  • Push & Go (selectable)
    • As the door is manually opened, the operator “senses” movement and opens door to the full-open position
  • Obstruction Detection
    • Open - Door closes if it hits an obstruction while opening
    • Close - Door will reverse to open position if it hits an obstruction while closing
    • Close (Selectable - Stop on Stall) - Door will stop once it hits an obstruction and will rest against the obstruction until removed

...

  • Motor Startup Delay
    • Delays operator opening for locking hardware
  • Infinite Hold Open
    • Door will hold open at set position until power is turned off
  • Power Close (Selectable)
  • Additional closing force to overcome conditions that might otherwise prevent the door from latching (ex: weather stripping, stack pressure)
  • Selector mode switch (3 position)
    • Off - door functions as a standard door closer
    • On - door functions as an automatic low energy operator
    • Hold Open - activates the unit to the hold open position

Benefits

SMART

  • Latch assist ensures door closes to secure facility
  • Occupant safety enhanced by obstruction detection, power assist, and push & go functions
  • Customizable inputs and outputs for accessories, including security override and fire safety

GOOD LOOKING

  • Unique design with slim profile blends seamlessly with frame
  • Low profile easily fits applications with minimal header space

 

...

SIMPLE

  • Modular design allows for one-person installation
  • Heavy-duty back plate serves as template simplifying and speeding installation
  • Unit learns door properties (approximate weight) during installation for easy programming and set-up
  • Easy to use controls simplify setup
  • Easy setup via a mobile device
  • USB port allows for quick software updates

Applications

Moderate to high traffic openings are ideal applications for the 6300 Series Low Energy Operator. Whether an interior or exterior door, the 6300 Series is a low energy door control solution that allows facilities to meet ADA (Americans with Disabilities Act) requirements by enabling a door to be operated through the use of push buttons, wave switches or hands-free radio frequency devices.

...

  • Corridors
  • Hospitals
  • Universities Entrance Doors
  • Schools
  • Theaters
  • Banks
  • Large office buildings
  • Large department stores

Electrical Data

  • Power input 120 VAC, 3A, 60Hz
  • Current draw 1.5A

...

  • Power output 24VDC @ 1.3A max draw (less accessories)

Certifications

 

  • ANSI/BHMA A156.19 certified
  • UL325/991 certified
  • UL10C listed for positive pressure fire test

 

...

 

  • Complies with requirements for the Americans with Disabilities Act (A.D.A)