All-in-one Door Kit Enables New York City Building Owners to Comply with Building Code Requiring ADA Compliant Trash Rooms

 

FEATURES & BENEFITS
5800 Series ADAEZ Trash Room Door Kit


» Easy to install
» Maintenance free
» Meets requirements for Americans
with Disabilities Act (ADA)
» GreenCircle® certified for energy use
» Occupancy sensor holds door open
while room is in use

» Controls doors up to 48” wide and
250 lbs. in weight
» Designed for Grade 1 heavy-duty
commercial use
» Brushless DC motor/gearbox tested
in excess of 10 million cycles

 

 

THE CHALLENGE


New York City’s building code mandates that trash rooms in newly
constructed and renovated high-rise residential buildings be equipped
with automated doors to make them fully accessible to disabled persons.
The Code stipulates that residents must have the ability to open trash
room doors using a wall push button (Knowing Act Switch). It also
requires that the door remains open until the space is vacated and closes
and re-latches automatically.

 


THE SOLUTION


The 5800 Series ADAEZ® Trash Room Door (TRD) kit from Norton is the
only automated door solution designed specifically for trash room doors.
The product is suitable for use with fire and smoke doors listed under
UL10C-90 minute rating.


The all-in-one kit dramatically simplifies the installation process. It
includes a door operator, 24VDC power supply cabinet with pre-wired
occupancy sensor and two wall push buttons (Knowing Act Switches).
Because the lock interface and occupancy sensor are pre-wired, it is easy
to install and requires no ongoing maintenance.


In addition, the ADAEZ TRD operator consumes only about 1 watt of
energy per year on average compared to traditional automated doors
which consume about 25 watts per year. In fact, GreenCircle® has certified
it to reduce energy consumption by as much as 91 percent versus other
comparable door operators.


The TRD system mounts on the door rather than above it to simplify
retrofit installations.

 

The all-in-one kit includes:


» Low voltage door operator
» Mounting hardware for virtually any door
and frame
» 24VDC 1 amp power supply
» Occupancy sensor
» Armored door cord
» (2) 1-3/4” surface mounted, stainless steel,
hardwired push buttons
» 20’ of operator power and signal wire
» Installation and operation manual
Note: the electric lock is not included but can be easily integrated into the kit.

 

Jeff Weinstein, vice president of Mayflower Sales Co., Inc., of Brooklyn,
NY, a long-time distributor of Assa Abloy products said, “We often hear
about architects, building owners and general contractors who are
unaware of this code requirement and incur costly project delays when
their building is denied a certificate of occupancy. This kit just makes it
incredibly easy for them to comply with this aspect of the building code
and keep their project schedule on track.”


Jay Vaitkus, director of Business Development for the Norton brand,
said, “The team at Mayflower Sales has been instrumental in not only
generating awareness of this building code requirement among New
York City architects and contractors but also in promoting the existence
of the 5800 Series ADAEZ Trash Room Door kit as a simple solution.”
Because the TRD system is pre-wired, it reduces on-site installation
time and costs. Once a certified electrician has connected the electrical
enclosure, a tradesperson simply mounts the operator to the door to
render the system immediately operational.


For more information and to order the 5800 Series ADAEZ Trash Room
Door (TRD) kit, contact your local Assa Abloy sales representative.